  1. LIFE WITHOUT A NEUTRAL CONDUCTOR IN A SUB – PANEL

    Dec 23, 2024 · The detached garage sub-panel, which used to be the main panel, is properly grounded with number #6 copper and is connected to an outside ground rod. EXISTING …

  2. Adding a subpanel with a gen transfer switch....

    Oct 28, 2024 · The well is a 30amp/240v circuit and the other 3 are 15amp/110v. My initial plan is to run 1 1/2 PVC conduit from main panel to sub panel. I will run 2 gauge copper from main …

  3. Adding Circuits to Subpanel | DIY Home Improvement Forum

    Jan 28, 2025 · The sub panel is hung next to the main panel, so they are inches from each other, wire connecting the two is about 2-3 ft long. Just to clarify, you are saying that since the sub …

  4. GE Breaker Panel with a Removable "Bonding Bar"

    Nov 22, 2023 · With the bonding screw in the panel, you would be bonding your grounds and neutrals again if you place a ground bar in the back of the panel to provide the separation …

  5. Running 2 AWG feeders to sub panel; Is conduit required...

    Jun 13, 2023 · I am running 2 gauge feeder wires (individual wires) from my main panel to a sub panel on a 125 amp double pole breaker. The main panel is mounted to the exterior wall of the …

  6. How to add exterior sub-panel off of Meter/Disconnect combo?

    Nov 6, 2023 · The other day I was asking about adding a subpanel inside to use for an EV charger (60A breaker) + workshop (50A or 60A). I've since had a couple electricians out to …

  7. Sub-panel ground neutral - DIY Home Improvement Forum

    Feb 17, 2025 · Hello, installing sub-panel to detached out building. From my inital research I have a basic diagram attached. I am hoping for verification that I am on the correct path so far. …

  8. Upgrading Garage Subpanel + Adding 240V - DIY Home …

    Dec 9, 2023 · Sub-panel in the detached garage It’s an old pushmatic breaker box. I believe it’s a 70-amp box. X2 20-amp breakers + x1 30-amp breaker. Only the input from the 50-amp …

  9. What is the correct way to route supply wire from main panel to ...

    May 15, 2020 · Here are my options: Option #1 and #2 - Sub-panel main lugs at top of panel. Service wire can enter from side of sub panel or bottom. (I'm not sure if option #2 would work …

  10. is there a load panel with pass through lugs - DIY Home …

    Feb 2, 2008 · Sure you can feed the 2nd sub-panel with a breaker in the 1st sub-panel. In fact this would be a more common installation than feed thru lugs. Sub-feed lugs like the THLK2125 …