  1. Condensate Drain Lines - The Building Code Forum

    May 1, 2017 · condensation water draining in to it, the bldg. sanitary sewer system will be trapped at some point, even if I connect to a wet vent. Restating my conundrum: An RDP has put …

  2. Condensate Disposal ( Residential ) | The Building Code Forum

    May 28, 2021 · Some jurisdictions will not let you dispose of the condensate into the sewer system simply because the volume of condensate drain within the jurisdiction will overload the …

  3. Condensation on suspended ceiling grid - The Building Code Forum

    Nov 2, 2009 · They are getting condensation in the tracks of the T-bar ceiling, and it is staining the lay-in ceiling tiles. He says the problem is everywhere, not just at the HVAC grilles or near …

  4. Why is water leaking from the furnace pipe in my attic?

    Oct 19, 2009 · I have a gas furnace that is approx 10 years old. There is a 5 inch galvanized furnace vent pipe in the attic that goes out the roof. Water is leaking from the seams of this …

  5. HVAC condensate line - The Building Code Forum

    Oct 18, 2020 · Recently had a new hvac system installed in one of my buildings. 5 T split system, they retained the ductwork, replaced the condensor and fan coil units. Question is about the …

  6. Microwave excessive condensaton | Heartland Owners Forum

    May 19, 2006 · Has anyone had an excessive condensation problem in the Sylvania microwaves that are being used in the Bighorns? I experienced this condensation problem last fall the first …

  7. SOLVED: Front cap leak... | Heartland Owners Forum

    Jun 4, 2018 · So I'm guessing it could possibly be condensation but could also be a leak. This morning I took the camper to a local county campground, to check things out. Well, the roof / …

  8. Norcold Refrigerator Drain - Heartland Owners Forum

    Jul 7, 2015 · My refer inside condensation collector backed up and I had several cups of water inside on the floor of the fridge. I pulled the drain hose out of the full rear drain pan and it the …

  9. Sprinkler in walk-in cooler - The Building Code Forum

    Oct 22, 2009 · Agree with what everyone has said. A few things on the install. 1. An intermediate (212F) temperature head is required by NFPA 13, 2007 ed. 2. Make sure if the cut a 3" hole …

  10. condensate drain line to floor drain - The Building Code Forum

    Oct 28, 2009 · Re: condensate drain line to floor drain 307.2.2 Drain pipe materials and sizes. Components of the condensate disposal system shall be cast iron, galvanized steel, copper, …